Accessories – Electromagnetic Compatibility | Induced RF | 4 kHz - 400 MHz | IEC 61000-4-6
Supplement your RF test system with the appropriate accessories, such as coupling and calibration components. For precise measurement results and maximum protection of your peripheral equipment during all tests against induced radio frequency.
| Type | Feature | ||
|---|---|---|---|
![]() | CDG 7000-200-4 | CDG 7000-200-4 Amplifier, Frequency range 4 kHz – 1 MHz Accessory for the CDG 7000-200 | more info |
![]() | CDN xxx CDG A 41xx | Coupling / decoupling networks (CDNs), Calibration adapters for CDNs, 50 /150 Ohm matching adapter and mouting plate | more info |
![]() | CDN EMCL-20 | EM Clamp for cable diameters < 20 mm | more info |
![]() | CDN EMCL-35 | EM Clamp for cable diameters < 35 mm | more info |
![]() | CDN ABCL-20 | Decoupling clamp for cable diameter < 20 mm | more info |
![]() | CDN ABCL-35 | Decoupling clamp for cable diameter < 35 mm | more info |
![]() | CDN EMCL-NW_10 | Matching network 10 kHz - 150 kHz for extending the range from CDN EMCL -20 to 10 kHz | more info |
![]() | CDN BCI-P1 CDN BCI-P1_MT-1 | CDN BCI-P1 - clamp bulk current injection (BCI) with calibration set The MT-1 transformer is required for the CDN BCI-P1 for MIL-STD-461 (CS114) and ISO 11452-4 (100 kHz - 400 MHz). | more info |
![]() | CDG CMP-45 | Current monitoring probe, foldable, with calibration set (ISO 11452-4, MIL-STD-461, DO-160) | more info |
![]() | CDG CMP-46 | Current monitoring probe (ISO 11452-4, MIL-STD-461, DO-160) | more info |
![]() | CDG 7006-20W | 6 dB Attenuator, 20 W | more info |
![]() | CDG 7006-100W | 6 dB Attenuator, 100 W | more info |
![]() | CDG 7006A-100W | 6 dB Attenuator, 100 W | more info |
![]() | CDG 7020-20W | 20 dB Attenuator, 20 W (MIL-STD-461, ISO 11452-4) | more info |
![]() | CDG A 50-10W | Termination (ISO 11452-4, MIL-STD-461) | more info |
![]() | SESD 270 | Reference ground plane, HCP – Horizontal Coupling Plane | more info |
![]() | HELIA 7 | Control software also available for BCI tests | more info |
Accessories – Electromagnetic Immunity, DC – 300 kHz | IEC 61000-4-16 / -19 | IEC 61543
To test your products for compliance with standards relating to low-frequency interference, our range of accessories, which complies with IEC 61000-4-16, IEC 61000-4-19 and IEC 61543 , is the ideal complement to your test generator. Ensure your test specimens are reliably protected whilst also safeguarding your laboratory electronics against unwanted feedback.
| Type | Feature | ||
|---|---|---|---|
![]() | CN 19 U-I | Coupling network with integrated current transformer (IEC 61000-4-19) | |
![]() | CN 19 U CN 19 I | Coupling network Current transformer (IEC 61000-4-19) | more info |
![]() | CN 1241 xx | Coupling networks, switchable (IEC 61000-4-16) | more info |
![]() | CN xxx | Coupling networks (IEC 61000-4-16) | more info |
![]() | CN 60255-C CN 60255-D | Coupling network for common / differential mode tests (IEC 60255-26) | more info |
![]() | IT-06 IT-16 IT-20 | Isolation transformer (IEC 61000-4-16, MIL-STD-461) | more info |
![]() | CN19 ZDIFF 1 Ohm | Shunt (IEC 61000-4-19) | more info |
![]() | CS 61543 | Shunt, 10 Ohm (IEC 61543) | more info |
![]() | CN19 Balun | Balun-Set: Impedance transformers for differential voltage tests - for tests with CN 19-U (IEC / EN 61000-4-19) | more info |