Coupling network CN 19 U with current transformer CN 19 I
IEC / EN 61000-4-19
The coupling network CN 19 U is suitable for differential voltage tests according to IEC / EC 61000-4-19. It is designed for tests in the frequency range from 2 kHz to 150 kHz.
The current transformer CN 19 I is used to supplement tests according to the IEC / EC 61000-4-19 standard and is also suitable for a frequency range from 2 kHz to 150 kHz.
CN 19 U
- Frequency range: 2 kHz – 150 kHz
- Level: 0...25 Vrms cont
- Source impedance: 10 Ω ±3 Ω max. (±1 Ω typical)
- EUT voltage: 500 V AC (50/60 Hz), 700 V DC
- Max. EUT current: 16 A cont. AC/DC
- Voltage drop mains EUT: 13 V typical (16 A/50 Hz)
- Amplifier input: XLR-female
- Mains/EUT: 4 mm safety sockets (black/blue)
- High voltage test amplifier - EUT: 1.9 kV DC (10 sec)
- Dimensions (H x W x D): 15.7 x 48.2 x 54 cm
- Weight: 11.2 kg
- Temperature range: 5...40 °C
CN 19 I: current transformer
- Frequency range: 2 kHz – 150 kHz
- Level: 0...10 Arms cont.
- Source impedance: 1 Ω ±0.3 Ω max. (±0.1 Ω typisch)
- Four-wire shunt: 0.1 Ω ±1 mΩ max.
- EUT voltage: 500 V AC (50/60 Hz), 700 V DC
- Amplifier input: XLR-female
- EUT current output: 4 mm safety sockets (black/blue)
- Shunt output: 4 mm 4 mm safety sockets (green)
- Power supply: external 24 V/1 A AC/DC-power supply unit
- High voltage test amplifier - current output: 1.9 kV DC (10 sec)