For Burst, Surge, Dips / Interrupts, Ring wave, Telekom wave, Magnetic field tests

AXOS 8

IEC / EN 61000-4-4
IEC / EN 61000-4-5
IEC / EN 61000-4-5 & ITU (with TW8)
IEC / EN 61000-4-9 (with MSURGE-A)
IEC / EN 61000-4-11 / -29 (with DIP 116)
IEC / EN 61000-4-12, ANSI/IEEE C62.41 

The new AXOS 8 compact test system from HAEFELY combines the advantages of standalone test systems in a single economical solution. This allows fast and fully automated testing to the most common IEC, EN, ANSI, IEEE and UL standards, such as 5 kV EFT/Burst, 7 kV Combination Wave (1.2/50 µs & 8/20 µs), AC/DC Dips & Interrupts (with DIP 116), Telecom Wave (10/700 µs, with TW8), 7 kV Ring Wave and Pulsed Magnetic Fields (with MSURGE-A). This test system includes an integrated 1-phase coupling filter up to 16 A.

The AXOS 8 test system can be controlled locally via touch screen or via remote control (optional) from a PC. The simple menu navigation and predefined tests allow efficient testing, even for less experienced users. Various additional functions such as external start/stop allow automated integration into customer-specific applications.

Kontakt / Contact
We will gladly advise you personally!

  • General:
    - Control power: 85 V - 264 V; 50/60Hz
    - Dimensions (W x H x D): 22"/6U (45 x 27 x 50 cm)
    - Display: 7" touchscreen
    - Weight: approx. 30 kg
  • EFT / Burst
    - Output voltage: 0.2 - 5.0 kV ±10% at coaxial output
    - Rise time: 5 ns ±30%
    - Pulse duration: 50 ns ±30% at 50 Ohm, 
      50 ns -15 +100 ns at 1000 Ohm
    - Burst mode: normal / continuous / real / random
  • Surge Combination Wave:
    - Output voltage: 0.2 - 7.0 kV ±10%
    - Voltage rise time / impulse duration:
      1.2 µs ±30% / 50 µs ±20%
    - Output current: 0.1 - 3.5 kA ±10%
    - Current rise time / impulse duration:
      8 µs ±20% / 20 µs ±20%
  • Telekom Wave (external TW8 module):
    - Max. Voltage: 0.2 - 7.0 kV ±10%
    - Rise time / decay time OCV: 10 µs ±30% / 700 µs ±30%
    - Rise time SCC: 5 µs ±20%
  • DIPS and INTERRUPTS (with DIP 116):
    - Max. voltage: 264 V AC/DC
    - Max. current: 16 A AC/DC cont,
      20 A for 5 s, 40 A for 3 s, > 500 A inrush current
  • Ring Wave:
    - Max. voltage: 0.2 - 7.0 kV ±10%
    - Frequency: 100 kHz
    - Rise time OC: 0.5 µs ±30%
    - Rise time SC: 0.2 µs ... 1 µs
  • Integrated single-phase CDN
    264 V AC / 16 A, 220 V DC / 10 A
  • Pulsed magnetic fields (with MSurge-A)

Integrated manual and automated test modes enable simple operation via the touchscreen or can be controlled via the PC using optional software. Software-supported test preparation, predefined test routines and visually supported test setups also save a lot of time and effort.

Automatic test reports can be generated, including test parameters, test setup and test result

  • Safe and reliable operation thanks to safety interlock, warning lamp and emergency stop switch
  • Voltage and current monitoring of surge pulses and EUT power

Compliance, pre-compliance, CE testing, product development and product troubleshooting