Pulse Generator PG 01-2000

FNN - Forum Network technology, Chapter 3.7.1 Guide for evaluating the reliability of electricity meters

The test generator PG 01-2000 is suitable for insulation test and testing of the impulse withstand voltage of electrical and electronic electricity meters. The generator produce a standard pulse voltage waveform with 0.1 / 2000 μs.

The forum network technology / network operations in the (German) VDE (FNN) has dealt with the issue of reliability of electricity meters and defines appropriate test methods. The requirements for the test generator PG 01-2000 are described in Chapter 3.7.1 of the FNN “Guidelines" for the evaluation of measurement reliability and stability of electricity meters and ancillary equipment.

Kontakt / Contact
We will gladly advise you personally!

  • Testing the surge voltage resistance of electrical and electronic electricity meters
  • Pulse voltage: adjustable from 4.0 - 10.0 kV
  • Polarity: positive, negative, alternating
  • Open circuit waveform: 0.1 / 2000 µs
  • Phase angle: 0° - 360
  • Mains-synchronous triggering
  • 1000:1 divider for checking the waveform
  • Memory function: for storing up to 32 settings
  • Size: 19'' housing (3 U)
  • Weight: 10 kg
  • Power supply: 100 - 240 VAC, 47 - 63 Hz, 100 VA
  • Operating temperature: 0 - 40 °C

The test voltage can be continuously adjusted from 4 kV - 10 kV.

With a standard voltage of the open-circuit waveform 0.1 / 2000 µs, the pulse generator fulfils the requirements of the FNN guideline, section 3.7.1.  The pulse voltage can be easily checked using the built-in 1000:1 divider.

T1: Rise time 0.1 ms
T2: Pulse width 2000 ms

Triggering is done manually, but can also be done externally.

Up to 32 device settings can be saved using the memory button. All changed parameters and button settings are saved. 

The EUT can be easily connected via an HV cable. The HV cable (1 metre) is included in the scope of delivery and is equipped with terminal strips on one side. This terminal strip must be integrated into a high-voltage insulated housing with contact protection.

The pulse generator can be used directly without additional accessories. 

The pulse generator can be easily integrated into a 19" rack. 